Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Clin Pharmacol Ther ; 105(4): 1031-1039, 2019 04.
Artigo em Inglês | MEDLINE | ID: mdl-30402880

RESUMO

M281 is a fully human, anti-neonatal Fc receptor (FcRn) antibody that inhibits FcRn-mediated immunoglobulin G (IgG) recycling to decrease pathogenic IgG while preserving IgG production. A randomized, double-blind, placebo-controlled, first-in-human study with 50 normal healthy volunteers was designed to probe safety and the physiological maximum for reduction of IgG. Intravenous infusion of single ascending doses up to 60 mg/kg induced dose-dependent serum IgG reductions, which were similar across all IgG subclasses. Multiple weekly doses of 15 or 30 mg/kg achieved mean IgG reductions of ≈85% from baseline and maintained IgG reductions ≥75% from baseline for up to 24 days. M281 was well tolerated, with no serious or severe adverse events (AEs), few moderate AEs, and a low incidence of infection-related AEs similar to placebo treatment. The tolerability and consistency of M281 pharmacokinetics and pharmacodynamics support further evaluation of M281 in diseases mediated by pathogenic IgG.


Assuntos
Anticorpos/metabolismo , Anticorpos/uso terapêutico , Antígenos de Histocompatibilidade Classe I/metabolismo , Imunoglobulina G/metabolismo , Receptores Fc/metabolismo , Adulto , Anticorpos/efeitos adversos , Método Duplo-Cego , Feminino , Voluntários Saudáveis , Humanos , Infusões Intravenosas/métodos , Masculino , Adulto Jovem
2.
Invest New Drugs ; 37(4): 711-721, 2019 08.
Artigo em Inglês | MEDLINE | ID: mdl-30569245

RESUMO

Adenosine suppresses antitumor immune responses via A2a and A2b receptors expressed on intratumoral immune cells. This effect is mediated by increased cyclic adenosine 5'-monophosphate (AMP) levels and phosphorylation of cyclic AMP response element binding protein (CREB). We conducted a phase 1, placebo-controlled, single-ascending-dose (SAD) and multiple-ascending-dose (MAD) study to assess the safety, tolerability, pharmacokinetics (PK), including food effect (FE), and pharmacodynamics (PD) of oral AB928, a novel dual A2aR/A2bR antagonist, in healthy volunteers. AB928 doses between 10 and 200 mg once daily and 100 mg twice daily were evaluated. The study enrolled 85 subjects (randomized 3:1, AB928:placebo), 40 each in the SAD and MAD cohorts, and 5 in the FE cohort. AB928 was well tolerated up to the highest dose tested and did not affect any physiologic parameters potentially sensitive to adenosine inhibition. No safety concern was identified. The PK profile of AB928 was linear and dose-proportional, and a clear PK/PD correlation was demonstrated. Significant inhibition of adenosine receptor-mediated phosphorylated CREB was observed at peak plasma concentrations in all dose cohorts and at trough plasma concentrations in the higher-dose cohorts. AB928 plasma levels ≥1 µM were associated with ≥90% adenosine receptor inhibition. In the postprandial state, the rate of AB928 absorption decreased but the extent of absorption was unchanged. Together, these data support further clinical development of oral AB928 in cancer patients.


Assuntos
Antagonistas de Receptores Purinérgicos P1/administração & dosagem , Administração Oral , Adolescente , Adulto , Linfócitos T CD8-Positivos/efeitos dos fármacos , Linfócitos T CD8-Positivos/metabolismo , Proteína de Ligação ao Elemento de Resposta ao AMP Cíclico/metabolismo , Método Duplo-Cego , Feminino , Interações Alimento-Droga , Voluntários Saudáveis , Humanos , Masculino , Pessoa de Meia-Idade , Antagonistas de Receptores Purinérgicos P1/sangue , Antagonistas de Receptores Purinérgicos P1/farmacocinética , Adulto Jovem
3.
J Cancer Res Clin Oncol ; 144(6): 1087-1095, 2018 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-29671069

RESUMO

PURPOSE: Pegfilgrastim is a long-acting granulocyte colony-stimulating factor indicated for prevention of febrile neutropenia in patients receiving myelosuppressive chemotherapy by promoting neutrophil recovery. METHODS: This phase 1, randomized, double-blind, three-way crossover trial in healthy volunteers evaluated the pharmacokinetics (PK), pharmacodynamics (PD), safety, and tolerability of the proposed biosimilar, comparing MYL-1401H, reference pegfilgrastim (Neulasta®, Amgen Inc, Thousand Oaks, CA, USA) sourced from the European Union, and reference pegfilgrastim sourced from the USA. Primary PK end points were peak plasma concentration of pegfilgrastim (Cmax) and area under the plasma concentration-time curve from the time of dosing to infinity (AUC0-inf). Primary PD end points were area under the curve above baseline for absolute neutrophil counts (ANC AUC0-t) and maximum change from baseline for ANC (ANC Cmax). Adverse events were also recorded. RESULTS: The primary PK and PD end points were similar across all groups. For the PK parameters, the 90% confidence intervals (CIs) of the ratios of geometric means ranged between 0.91 and 1.18, which were within the predefined bioequivalence interval of 0.8000 to 1.2500 for all comparisons. For the PD parameters, the 95% CIs of the ratios of geometric means ranged between 0.94 and 1.06 for all comparisons, which were within the predefined PD equivalence interval of 0.8500 to 1.1765. The safety profiles were similar, with the most common adverse events being back pain and headache. CONCLUSIONS: MYL-1401H demonstrated similar PK, PD, and safety to reference pegfilgrastim in healthy volunteers and may be an equivalent option for the prevention of febrile neutropenia.


Assuntos
Medicamentos Biossimilares/farmacologia , Medicamentos Biossimilares/farmacocinética , Filgrastim/farmacologia , Filgrastim/farmacocinética , Polietilenoglicóis/farmacologia , Polietilenoglicóis/farmacocinética , Adulto , Medicamentos Biossimilares/efeitos adversos , Neutropenia Febril Induzida por Quimioterapia/sangue , Neutropenia Febril Induzida por Quimioterapia/etiologia , Estudos Cross-Over , Método Duplo-Cego , Feminino , Filgrastim/efeitos adversos , Humanos , Masculino , Polietilenoglicóis/efeitos adversos , Equivalência Terapêutica
4.
BMC Gastroenterol ; 18(1): 3, 2018 Jan 05.
Artigo em Inglês | MEDLINE | ID: mdl-29304731

RESUMO

BACKGROUND: Pathogenesis in non-alcoholic steatohepatitis (NASH) involves abnormal cholesterol metabolism and hepatic accumulation of toxic free cholesterol. Apical sodium-dependent bile acid transporter (ASBT) inhibition in the terminal ileum may facilitate removal of free cholesterol from the liver by reducing recirculation of bile acids (BAs) to the liver, thereby stimulating new BA synthesis from cholesterol. The aim of this phase 1 study in adult healthy volunteers (HVs) and patients with type 2 diabetes mellitus (T2DM) was to assess the safety, tolerability, pharmacokinetics and pharmacodynamics of ASBT inhibition with volixibat (SHP626; formerly LUM002). METHODS: Participants were randomised 3:1 to receive once-daily oral volixibat (0.5 mg, 1 mg, 5 mg or 10 mg) or placebo for 28 days in two cohorts (HV and T2DM). Assessments included safety, faecal BA and serum 7α-hydroxy-4-cholesten-3-one (C4; BA synthesis biomarker). RESULTS: Sixty-one individuals were randomised (HVs: placebo, n = 12; volixibat, n = 38; T2DM: placebo, n = 3; volixibat, n = 8). No deaths or treatment-related serious adverse events were reported. Mild or moderate gastrointestinal adverse events were those most frequently reported with volixibat. With volixibat, mean total faecal BA excretion on day 28 was ~1.6-3.2 times higher in HVs (643.73-1239.3 µmol/24 h) and ~8 times higher in T2DM (1786.0 µmol/24 h) than with placebo (HVs: 386.93 µmol/24 h; T2DM: 220.00 µmol/24 h). With volixibat, mean C4 concentrations increased by ~1.3-5.3-fold from baseline to day 28 in HVs and by twofold in T2DM. CONCLUSIONS: Volixibat was generally well tolerated. Increased faecal BA excretion and serum C4 levels support the mechanistic rationale for exploring ASBT inhibition in NASH. The study was registered with the Dutch clinical trial authority (Centrale Commissie Mensgebonden Onderzoek; trial registration number NL44732.056.13; registered 24 May 2013).


Assuntos
Benzotiepinas/administração & dosagem , Benzotiepinas/efeitos adversos , Diabetes Mellitus Tipo 2/tratamento farmacológico , Glicosídeos/administração & dosagem , Glicosídeos/efeitos adversos , Glicoproteínas de Membrana/antagonistas & inibidores , Hepatopatia Gordurosa não Alcoólica/tratamento farmacológico , Transportadores de Ânions Orgânicos Dependentes de Sódio/antagonistas & inibidores , Simportadores/antagonistas & inibidores , Adolescente , Adulto , Idoso , Benzotiepinas/farmacocinética , Ácidos e Sais Biliares/análise , Ácidos e Sais Biliares/metabolismo , Glicemia/metabolismo , Colestenonas/sangue , Diabetes Mellitus Tipo 2/metabolismo , Método Duplo-Cego , Fezes/química , Feminino , Glicosídeos/farmacocinética , Homeostase , Humanos , Metabolismo dos Lipídeos , Masculino , Pessoa de Meia-Idade , Adulto Jovem
5.
Sci Transl Med ; 9(387)2017 04 26.
Artigo em Inglês | MEDLINE | ID: mdl-28446688

RESUMO

Conventional cytotoxic chemotherapy is highly effective in certain cancers but causes dose-limiting damage to normal proliferating cells, especially hematopoietic stem and progenitor cells (HSPCs). Serial exposure to cytotoxics causes a long-term hematopoietic compromise ("exhaustion"), which limits the use of chemotherapy and success of cancer therapy. We show that the coadministration of G1T28 (trilaciclib), which is a small-molecule inhibitor of cyclin-dependent kinases 4 and 6 (CDK4/6), contemporaneously with cytotoxic chemotherapy protects murine hematopoietic stem cells (HSCs) from chemotherapy-induced exhaustion in a serial 5-fluorouracil treatment model. Consistent with a cell-intrinsic effect, we show directly preserved HSC function resulting in a more rapid recovery of peripheral blood counts, enhanced serial transplantation capacity, and reduced myeloid skewing. When administered to healthy human volunteers, G1T28 demonstrated excellent in vivo pharmacology and transiently inhibited bone marrow (BM) HSPC proliferation. These findings suggest that the combination of CDK4/6 inhibitors with cytotoxic chemotherapy should provide a means to attenuate therapy-induced BM exhaustion in patients with cancer.


Assuntos
Células-Tronco Hematopoéticas/efeitos dos fármacos , Animais , Células da Medula Óssea/citologia , Células da Medula Óssea/efeitos dos fármacos , Pontos de Checagem do Ciclo Celular/efeitos dos fármacos , Proliferação de Células/efeitos dos fármacos , Quinase 4 Dependente de Ciclina/antagonistas & inibidores , Quinase 4 Dependente de Ciclina/metabolismo , Quinase 6 Dependente de Ciclina/antagonistas & inibidores , Quinase 6 Dependente de Ciclina/metabolismo , Feminino , Fluoruracila/farmacologia , Voluntários Saudáveis , Células-Tronco Hematopoéticas/citologia , Humanos , Masculino , Camundongos , Camundongos Endogâmicos C57BL
6.
Br J Clin Pharmacol ; 75(5): 1221-30, 2013 May.
Artigo em Inglês | MEDLINE | ID: mdl-22978318

RESUMO

AIM: Conjugation to antithrombin III ATIII-binding pentasaccharides has been proposed as a novel method to extend the half-life of therapeutic proteins. We aim to validate this technological concept in man by performing a first-in-human study using CarboCarrier® insulin (SCH 900948) as an example. A rising single dose phase 1 study was performed assessing safety, tolerability, pharmacokinetics and relative bioactivity of CarboCarrier® insulin. Safety, tolerability and pharmacokinetics (PK) of single doses of CarboCarrier® insulin in healthy volunteers were explored, and the dose-response relationship and relative bioactivity of CarboCarrier® insulin in subjects with type 2 diabetes were investigated. METHODS: After an overnight fast, subjects were randomized to a treatment sequence. PK and pharmacodynamic (glucose, insulin and C-peptide) samples were obtained for up to 72 h post-dose. Effects of CarboCarrier® insulin were compared with those of NPH-insulin. RESULTS: CarboCarrier® insulin was safe and well-tolerated and no consistent pattern of adverse events occurred. CarboCarrier® insulin exposure (Cmax and AUC) increased proportionally with dose. The mean terminal elimination half-life ranged between 3.11 and 5.28 h. All CarboCarrier® insulin dose groups showed decreases in the mean change from baseline of plasma glucose concentrations compared with the placebo group. CONCLUSIONS: CarboCarrier® insulin is pharmacologically active showing features of insulin action in man. The elimination half-life of the molecule was clearly extended compared with endogenous insulin, indicating that conjugation to ATIII-binding pentasaccharides is a viable approach to extend the half-life of therapeutic proteins in humans. This is an important step towards validation of the CarboCarrier® technology by making use of CarboCarrier® insulin as an example.


Assuntos
Diabetes Mellitus Tipo 2/metabolismo , Portadores de Fármacos , Glicoproteínas/farmacocinética , Hipoglicemiantes/farmacocinética , Insulina de Ação Prolongada/farmacocinética , Adolescente , Adulto , Idoso , Área Sob a Curva , Disponibilidade Biológica , Glicemia/metabolismo , Peptídeo C/sangue , Diabetes Mellitus Tipo 2/tratamento farmacológico , Relação Dose-Resposta a Droga , Feminino , Hemoglobinas Glicadas/metabolismo , Glicoproteínas/química , Meia-Vida , Humanos , Hipoglicemiantes/química , Injeções Subcutâneas , Insulina/sangue , Insulina de Ação Prolongada/química , Masculino , Pessoa de Meia-Idade , Oligossacarídeos/química , Adulto Jovem
7.
Eur J Clin Pharmacol ; 68(3): 249-58, 2012 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-21935705

RESUMO

PURPOSE: The aim of our study was to evaluate the pharmacology of vorapaxar (SCH 530348), an oral PAR-1 antagonist, in healthy volunteers. METHODS AND RESULTS: In two randomized, placebo-controlled studies, subjects received either single ascending doses of vorapaxar (0.25, 1, 5, 10, 20, or 40 mg; n = 50), multiple ascending doses of vorapaxar (1, 3, or 5 mg/day for 28 days; n = 36), a loading dose (10 or 20 mg) followed by daily maintenance doses (1 mg) for 6 days (n = 12), or placebo. Single 20- and 40-mg doses of vorapaxar completely inhibited thrombin receptor activating peptide (TRAP)-induced platelet aggregation (>80% inhibition) at 1 h and sustained this level of inhibition for ≥72 h. Multiple doses yielded complete inhibition on Day 1 (5 mg/day) and Day 7 (1 and 3 mg/day). Adverse events were generally mild, transient, and unrelated to dose. CONCLUSION: Vorapaxar provided rapid and sustained dose-related inhibition of platelet aggregation without affecting bleeding or clotting times.


Assuntos
Lactonas/administração & dosagem , Inibidores da Agregação Plaquetária/administração & dosagem , Agregação Plaquetária/efeitos dos fármacos , Piridinas/administração & dosagem , Receptor PAR-1/antagonistas & inibidores , Adolescente , Adulto , Tempo de Sangramento , Feminino , Humanos , Lactonas/sangue , Lactonas/farmacocinética , Masculino , Pessoa de Meia-Idade , Inibidores da Agregação Plaquetária/sangue , Inibidores da Agregação Plaquetária/farmacocinética , Piridinas/sangue , Piridinas/farmacocinética , Adulto Jovem
8.
Ned Tijdschr Geneeskd ; 154: A762, 2010.
Artigo em Holandês | MEDLINE | ID: mdl-20456775

RESUMO

A 58-year-old man, who spoke very little Dutch, had various symptoms and used several drugs including simvastatin. He was prescribed itraconazole for onychomycosis. Simvastatin was concurrently replaced with pravastatin to prevent drug interactions. However, the interaction still occurred when the pravastatin ran out, and the patient resumed taking simvastatin on his own initiative. Myalgia and muscle weakness developed after one week. The general practitioner found a strongly elevated creatine kinase level in the blood. The patient required hospitalisation for severe rhabdomyolysis. He was treated with an infusion of an ample quantity of physiological saline solution and made a full recovery. Due to the elevated risk of toxic interactions, doctors should beware of communication problems in complex patients and avoid new prescriptions not strictly required.


Assuntos
Antifúngicos/efeitos adversos , Hipolipemiantes/efeitos adversos , Itraconazol/efeitos adversos , Rabdomiólise/induzido quimicamente , Sinvastatina/efeitos adversos , Antifúngicos/uso terapêutico , Interações Medicamentosas , Humanos , Hipolipemiantes/uso terapêutico , Itraconazol/uso terapêutico , Masculino , Pessoa de Meia-Idade , Rabdomiólise/terapia , Sinvastatina/uso terapêutico
9.
Biomed Mater Eng ; 14(4): 455-64, 2004.
Artigo em Inglês | MEDLINE | ID: mdl-15472394

RESUMO

Glucose or lactate biosensors are very useful for monitoring metabolism. Continuous monitoring of glucose is for example very important in diabetic patients. The measurement of lactate, a marker for oxygen deficiency, is used in the intensive care unit to monitor the patients' condition. In our laboratory we have developed two types of on-line biosensors to measure in vivo glucose and lactate: a sandwich-type biosensor and, very recently, a miniaturized flow-through biosensor. These biosensors are not placed in the body itself, but are connected to implanted microdialysis or ultrafiltration probes. Both types of biosensors are based on the oxidation of substrate using glucose oxidase or lactate oxidase and electrochemical detection. In the sandwich-type sensor, the enzymes are physically immobilized between two cellulose nitrate filters, and operate with ferrocene as a mediator. In the miniaturized biosensor, with an internal volume of 10-20 nanolitres, the enzymes are immobilized on the electrode via in situ encapsulation in poly(1,3-phenylenediamine). In this review we shall explain the working of these biosensors, and describe their application in clinical monitoring and experimental research.


Assuntos
Técnicas Biossensoriais/instrumentação , Biotecnologia/instrumentação , Análise Química do Sangue/instrumentação , Glicemia/análise , Diabetes Mellitus/sangue , Diabetes Mellitus/diagnóstico , Ácido Láctico/sangue , Técnicas Biossensoriais/métodos , Técnicas Biossensoriais/tendências , Biotecnologia/métodos , Biotecnologia/tendências , Análise Química do Sangue/métodos , Análise Química do Sangue/tendências , Desenho de Equipamento , Humanos , Monitorização Fisiológica/instrumentação , Monitorização Fisiológica/métodos , Monitorização Fisiológica/tendências , Pesquisa/instrumentação , Pesquisa/tendências , Projetos de Pesquisa , Avaliação da Tecnologia Biomédica
10.
Life Sci ; 70(21): 2457-66, 2002 Apr 21.
Artigo em Inglês | MEDLINE | ID: mdl-12173410

RESUMO

The abdominal subcutaneous interstitium is easily accessible for monitoring glucose for Diabetes Mellitus research and management. The available glucose sensing devices demand frequent blood sampling by finger pricking for calibration. Moreover, there is controversy about the exact relationship between the levels of glucose in the subcutis and blood. In the present study ultra-slow microdialysis was applied for subcutaneous fluid sampling, allowing continuous measurement of glucose in an equilibrated fluid using a nanolitre size sensor. The present method avoids in vivo calibration. During an oral glucose tolerance test glucose levels were measured simultaneously in blood, in adipose tissue and loose connective tissue layers of the abdominal subcutis in seven healthy subjects. Fasting glucose levels (mM) were 2.52 +/- 0.77 in adipose tissue and 4.67 +/- 0.17 in blood, this difference increasing to 6.40 +/- 1.57 and 11.59 +/- 1.52 at maximal glucose concentration. Moreover, the kinetics of glucose in blood and adipose tissue were different. In contrast, connective tissue glucose levels differed insignificantly (4.71 +/- 0.21 fasting and 11.70 +/- 1.96 at maximum) from those in blood and correlated well (r2 = 0.962). Ultra-slow microdialysis combined with a nanolitre glucose sensor could be of benefit to patients in intensive diabetes therapy. Frequent blood sampling for in vivo calibration can be avoided by monitoring glucose in the abdominal subcutaneous loose connective tissue, rather than in the adipose tissue.


Assuntos
Glucose/metabolismo , Pele/química , Pele/metabolismo , Tecido Adiposo/química , Tecido Adiposo/metabolismo , Técnicas Biossensoriais , Automonitorização da Glicemia/instrumentação , Tecido Conjuntivo/química , Tecido Conjuntivo/metabolismo , Teste de Tolerância a Glucose , Humanos , Insulina/sangue , Microdiálise , Valores de Referência
11.
Clin Chim Acta ; 316(1-2): 1-10, 2002 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-11750268

RESUMO

BACKGROUND: Tight regulation of blood glucose levels from patients suffering from diabetes mellitus can significantly reduce the complications associated with this disease. For this reason, elaborate research efforts have been devoted to the development of a glucose sensor for the continuous in vivo monitoring of glucose. Although the use of microdialysis as a sampling interface between the body and the biosensor is widely accepted, a major drawback of conventional microdialysis is the limited in vivo recovery. Here, ultraslow microdialysis is proposed in order to obtain (near) quantitative in vivo recoveries. To avoid, however, unacceptable long delay times, the need for a small and low dead volume measuring device was recognised. METHODS: A portable lightweight measuring device for continuous in vivo monitoring of glucose in subcutaneous tissue is presented. The measuring device consists of a miniaturised flow-through biosensor, connected to a microdialysis probe and a semi-vacuum pump. The biosensor is based on the amperometric detection of hydrogen peroxide after conversion of glucose by immobilised glucose oxidase. A portable potentiostat equipped with data logging is used for detection and registration. RESULTS: The device was validated for its accuracy, precision, linearity, sensitivity, selectivity and stability during ex vivo and in vivo experiments. The linearity was found to be up to 30 mmol/l with a limit of detection of 0.05 mmol/l. The precision, depending on the biosensor tested was found to be 2-4%. No contribution to the signal could be observed from several tested electroactive species. The accuracy was found to be well in accordance with the criteria set for methods of Self Monitoring of Blood Glucose for patients with diabetes mellitus. The biosensors could be used for up to 3 days in the continuous mode. In vivo monitoring of glucose in dialysate of subcutaneous sampled tissue during glucose tolerance tests in healthy volunteers demonstrated the potential of this measuring device. CONCLUSIONS: A portable lightweight measuring device is presented which can measure continuously glucose in vivo without excessive calibration steps. The performance characteristics determined justify the application of this measuring device for the in vivo monitoring of glucose in subcutaneous sampled interstitium of diabetic patients.


Assuntos
Técnicas Biossensoriais/instrumentação , Automonitorização da Glicemia/instrumentação , Técnicas Biossensoriais/métodos , Técnicas Biossensoriais/normas , Automonitorização da Glicemia/métodos , Automonitorização da Glicemia/normas , Calibragem , Diabetes Mellitus/sangue , Diálise , Feminino , Glucose Oxidase/metabolismo , Teste de Tolerância a Glucose , Humanos , Peróxido de Hidrogênio/análise , Miniaturização , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...